Econimic Series

Introduction

Main Features

  • OEM applications
  • Excellent price/performance ratio
  • Stainless Steel or brass construction
  • Compact design

Applications

  • Pneumatic
  • HVAC
  • Factory automation
  • Energy
  • Agriculture vehicles

Measuring ranges and overpressure safety

Pressure range -1 ... 0
0 ... 1
-1 ... 1.5
0 ... 2.5
-1 ... 3
0 ... 4
-1 ... 5
0 ... 6
-1 ... 9
0 ... 10
-1 ... 15
0 ... 16
-1 ... 24
0 ... 25
1 ... 39
0 ... 40
0 ... 60 0 ... 100 0 ... 160 0 ... 200
Over pressure 2 4 8 12 20 32 50 80 120 200 320 360
Burst pressure 3 7 12 18 30 48 75 120 180 300 480 480

Technical Specifications

Measuring principle   Thick film on ceramic  
Measuring ranges -1 ... 0 bar up to 0 ... 200 bar
Type of pressure   Relative
Accuracy (20 °C) (linearity, hysteresis and repeatability according Best   ≤ ± 0.5% FS (BFSL)
Error of zero point ≤ ± 1% FS
Error of span  ≤ ± 1% FS
Zero thermal drift ≤ ± 0.25% FS/10 K
Span thermal drift   ≤ ± 0.15% FS/10 K
Long term stability ≤ 0.3% FS / Year
Response time  (10 … 90%) ≤ 3 ms
Process connections See page 3