Introduction

Main Features
- OEM applications
- Excellent price/performance ratio
- Stainless Steel or brass construction
- Compact design
Applications
- Pneumatic
- HVAC
- Factory automation
- Energy
- Agriculture vehicles
Measuring ranges and overpressure safety
Pressure range | -1 ... 0 0 ... 1 |
-1 ... 1.5 0 ... 2.5 |
-1 ... 3 0 ... 4 |
-1 ... 5 0 ... 6 |
-1 ... 9 0 ... 10 |
-1 ... 15 0 ... 16 |
-1 ... 24 0 ... 25 |
1 ... 39 0 ... 40 |
0 ... 60 | 0 ... 100 | 0 ... 160 | 0 ... 200 | ||||||||||||
Over pressure | 2 | 4 | 8 | 12 | 20 | 32 | 50 | 80 | 120 | 200 | 320 | 360 | ||||||||||||
Burst pressure | 3 | 7 | 12 | 18 | 30 | 48 | 75 | 120 | 180 | 300 | 480 | 480 |
Technical Specifications
Measuring principle | Thick film on ceramic |
Measuring ranges | -1 ... 0 bar up to 0 ... 200 bar |
Type of pressure | Relative |
Accuracy (20 °C) (linearity, hysteresis and repeatability according Best | ≤ ± 0.5% FS (BFSL) |
Error of zero point | ≤ ± 1% FS |
Error of span | ≤ ± 1% FS |
Zero thermal drift | ≤ ± 0.25% FS/10 K |
Span thermal drift | ≤ ± 0.15% FS/10 K |
Long term stability | ≤ 0.3% FS / Year |
Response time (10 … 90%) | ≤ 3 ms |
Process connections | See page 3 |